Flashing: Brick’s Best Defense Against Water Penetration
Scroll Button

Flashing: Brick’s Best Defense Against Water Penetration

In our colder northern climate, water penetration is the most common source of masonry brick failure. When water freezes, it expands. If this expansion takes place in the pore spaces of a brick or between the brick and mortar, cracks are likely to form and propagate. The severity of the cracking may increase until the damage is repaired or the walls fail completely with additional expansion cycles. flashing

Water will also carry salts into walls, either leached from cement in the mortar or percolated from the ground. As the water evaporates, salt crystals (florescence) form either on the surface of the brick (efflorescence) or within the pores of the brick (cryptoflorescence). Efflorescence is unsightly but does not usually damage brick by itself. Cryptoflorescence, however, can seal water into brick pores, causing expansion damage, or damage to the brick directly as the salt crystals expand.

Through-Wall Flashing

Brick walls that are designed to shed water are the most desirable. However, through-wall flashing provides the best defense against water penetration. Through-wall flashing is an impermeable membrane placed in the wall that extends from the sheathing, across the air space, and all the way to the exterior of the brickwork. Properly installed flashing keeps water from penetrating through a wall face. Through-wall flashing at grade level prevents water from seeping into the upper section of a wall from the below-grade masonry.

Flashing should be placed at all points where the air space is closed off. Standard building codes require flashing at the foundation, above window and door heads, at window sills, and where the roof of a one-story wing meets a two-story brick veneer wall.

Flashing should extend from the outside face of the veneer through the thickness of the brick, across the air space to the backing, and then up at least 8 inches. The flashing should either extend up behind the water resistant barrier or be attached to its surface with a termination bar. Flashing held back from the outside of the brick veneer — even just ½ inch — may allow water to enter the wall.

Flashing that is punctured will not perform as intended and should be torn out and replaced. Where flashing under a brick course requires more than piece, flashing pieces should be overlapped at least 6 inches and sealed with compatible mastic.

Because the expense and difficulty of replacing flashing is considerable, only the best materials should be used. Copper and copper alloys, stainless steel, bituminous membranes, and combinations of such materials are suitable for flashing. Aluminum and building felt should not be used.